EARTHQUAKE SWITCH

DEPSEN switches the moving elevator to earthquake mode, as it senses the earthquake
DEPSEN activates the emergency rescue system for the evacuation of the elevator, which was stopped during the earthquake.
DEPSEN is a device that is designed to obstruct the hazards which will be able after earthquake in the elevator.
DEPSEN is a single-pole, double-throw svvitch, with one normally öpen contacts, one normally closed contacts, and one ground contacts.
Mount the Depsen to the wall or other rigid support with screws or butterfly anchors. Level the unit by adjusting the 4 elevator feet so that the chain on the side of the unit passes through the hole Ýn its bracket without touching the sides of the hole. Connect conduit and wire per applicable code requirements. DEPSEN must be manually reset as figures.

 
DIMENSIONS
ELEKTRICAL RATINGS


10 A at 125-, 250VAC;
0.25 A at 250 VDC; 0.50 A at 125 VDC
.5HP at 125 VAC; 1 HP at 250 VAC


SEISMIC RESPONSE


Depsen is set to trip as follows:


• Between 0.10 g and 0.25 g horizontal acceleration at 1 CPS;
• Between 0.15 g and 0.30 g horizontal acceleration at 2.5 CPS;
• Between 0.20 g and 0.40 g horizontal acceleration at 5 CPS;

Below 0.70 g horizontal acceleration at 7.5 CPS; &
• Above 0.40 g horizontal acceleration at 10 CPS.

 

RESETING OF EARTHQUAKE SWITCH

 

 